Release Notes - Events2HVAC Event Automation - Version 1.5.0
Note: This is a recommended update for all previous versions.
Upgrade Information
If you are upgrading from v1.3.x or earlier versions, please review the system requirement changes section below.
- The latest version of .NET framework 4.5.2 or 4.6.x may require a server restart after installation.
- Makes sure you are not using SQL 2005 (v9.0.x) for the Events2HVAC database before you try to upgrade. The update scripts might fail with this version.
- Make sure you make database backups as with any upgrade. If there is a problem during upgrade and you need to revert back to the previous version, you must have a database backup of the previous version.
- If you want to take advantage of the Professional edition features (multiple event providers), you will need to upgrade your license to Professional.
- Your existing license will work as a "standard" edition license.
- Make sure you "Rediscover" your device interfaces if you are using any of the new actions in this release. Device Interface Manager - Rediscover Devices
Please review this link before updating software:
Improvements & Fixes
- New Feature: BACnet local object visible for scheduler online status so that automatic failover to HVAC schedules can be performed on BACnet controllers.
- New Feature: Allow multiple BACnet heartbeat targets to push heartbeats to controllers for schedule failover.
- New Feature: Allow multiple JCI MSEA heartbeat targets to push heartbeats to controllers for schedule failover.
- New Feature: Add a minimum stop gap time to equipment zones to prevent short cycling between last event stop and new event start.
- New Event Provider: e360 ChMS Event Provider.
- Improvement: Enable schedule importer to fail event queries if event cache is unreliable.
- Improvement: Allow R25 users to use “X25 Building” custom attribute for room building names instead of partition name.
- Improvement: Enable schedule importer to fail event queries if event cache is unreliable.
- Improvement: Allow user to ignore a version update alert
- Fix: Rebuild rooms doesn’t clear old rooms if local cache has events stored for the rooms.
- Fix: Alert message screens don’t get properly removed in UI.
- Fix: Schedule importer event provider doesn’t flag missing events as deleted in the event cache.
- Fix: Don’t allow schedule importer users to select remote queries in event viewers.
- Fix: Some exchange errors were getting masked as a different error.
- Fix: P2000 request/response logging was not working.
- Fix: Re-initialize command from client does not properly reinitialize device manager.
- Fix: Changing a user subscription should prompt a restart of the service.
- Fix: Support all BACnet exception schedule datatypes (for Tridium).
- Fix: Misc bug fixes when testing SendExceptionSchedule actions.
- Fix: SendExceptionSchedule action was not handling events that crossed midnight correctly.
- Fix: Performance issue with logger and large log files
- Update XML-RPC component for P2000 to v2.5.0.1.
- Allow corrupt EMS and ChMS event schedules to be ignored instead of failing entire query.
- Meeting Planner Event Provider is obsolete and no longer supported.
- Documentation updates